Virtual Connect domains 35
Trap Category Severity MIB
vcFcFabricManagedStatusChanged
3
VCM Fabric Status Corresponds to the
name of the new state
VCD-MIB
VC module status change (deprecated)
— — —
vcModuleManagedStatusChanged
3
VC-Enet Module Status or
VC-FC Module Status
Corresponds to the
name of the new state
VCD-MIB
Profile status change (deprecated)
— — —
vcProfileManagedStatusChanged
3
VCM Profile Status Corresponds to the
name of the new state
VCD-MIB
Physical server change (deprecated)
— — —
vcPhysicalServerManagedStatusChang
ed
3
VCM Server Status Corresponds to the
name of the new state
VCD-MIB
vcTesttrap
VCM Domain Status INFO VCD-MIB
Enet IF-MIB LinkDown
VC-Enet Port Status INFO IF-MIB
Enet IF-MIB LInkUp
VC-Enet Port Status NORMAL IF-MIB
Input utilization above high-water mark²
VC-Enet Port Threshold WARNING VCM-MIB
Input utilization below low-water mark²
VC-Enet Port Threshold NORMAL VCM-MIB
Output utilization above high-water
mark²
VC-Enet Port Threshold WARNING VCM-MIB
Output utilization below low-water
mark²
VC-Enet Port Threshold NORMAL VCM-MIB
Input errors above high-water mark²
VC-Enet Port Threshold WARNING VCM-MIB
Input errors below low-water mark²
VC-Enet Port Threshold NORMAL VCM-MIB
Output errors above high-water mark²
VC-Enet Port Threshold WARNING VCM-MIB
Output errors below low-water mark²
VC-Enet Port Threshold NORMAL VCM-MIB
vcModPortBpduLoopDetected
VC-Enet Port Status CRITICAL VCM-MIB
vcModPortBpduLoopCleared
VC-Enet Port Status INFO VCM-MIB
vcModPortProtectionConditionDetected
VC-Enet Port Status CRITICAL VCM-MIB
vcModPortProtectionConditionCleared
VC-Enet Port Status INFO VCM-MIB
¹ Only supported by the HP VC 8Gb 24-Port FC module
² The VC Module MIB has the capability to send traps when certain bandwidth and throughput utilization thresholds are
reached. The counters are sampled at a fixed interval of 30 seconds and neither sample interval nor threshold values are
configurable in this release. Thresholds are defined as follows:
— Port utilization high water mark 95%
— Port utilization low water mark 75%
— Errors high water mark 5%
— Errors low water mark 1%
For more information, see the description field in the source code for individual MIBs.
3
For more information, see "VC Domain Managed Status Changed traps (on page 38)."
IMPORTANT: During OA failover or other management network disruptions, VC SNMP traps
might not reach the management station.
The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus
element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap severities
to the VC Domain MIB's trap severity definitions.
connUnitPortStatus value Severity
unknown
INFO
unused
INFO